Rectification and repair of a faulty air conditioner – mechanical engineering project topics – complete project topic
Table Of Contents
Chapter ONE
INTRODUCTION
- 1.1Introduction
- 1.2Background of Study
- 1.3Problem Statement
- 1.4Objective of Study
- 1.5Limitation of Study
- 1.6Scope of Study
- 1.7Significance of Study
- 1.8Structure of the Research
- 1.9Definition of Terms
Chapter TWO
LITERATURE REVIEW
- 2.1Overview of Air Conditioning Systems
- 2.2Common Faults in Air Conditioners
- 2.3Importance of Regular Maintenance
- 2.4Energy Efficiency in Air Conditioning
- 2.5Emerging Technologies in Air Conditioning
- 2.6Environmental Impact of Air Conditioning
- 2.7Consumer Trends in Air Conditioning
- 2.8Regulations and Standards in Air Conditioning
- 2.9Cost Analysis of Air Conditioning Systems
- 2.10Case Studies and Best Practices
Chapter THREE
SYSTEM DESIGN AND IMPLEMENTATION
- 3.1Research Design
- 3.2Data Collection Methods
- 3.3Sampling Techniques
- 3.4Data Analysis Procedures
- 3.5Research Instruments
- 3.6Ethical Considerations
- 3.7Reliability and Validity
- 3.8Limitations of the Methodology
Chapter FOUR
SYSTEM TESTING AND EVALUATION
- 4.1Overview of Findings
- 4.2Analysis of Data
- 4.3Comparison with Literature Review
- 4.4Key Observations
- 4.5Trends and Patterns
- 4.6Implications of Findings
- 4.7Recommendations for Practice
- 4.8Areas for Future Research
Chapter FIVE
SUMMARY, CONCLUSION AND RECOMMENDATIONS
- 5.1Summary of Research
- 5.2Conclusions
- 5.3Contributions to Knowledge
- 5.4Practical Implications
- 5.5Recommendations for Action
- 5.6Reflections on the Research Process
- 5.7Areas for Further Study
- 5.8Closing Remarks
Thesis Abstract
In the mechanical Engineering department of institute of management and technology there and many machines but not all in are good shape or form.
This may be due to inadequate maintenance, which is evident in the breakdown of air conditioner. In the case of machine maintenance, the quality and effusiveness of material were well noted. Also not left behind was the cost of maintenance which was minimized and yet getting to a highly successful repairs too.
In so long, during the repairs and rehabilitation of a faulty air conditioner appropriate tools, cost and quality of material were well considered.#
Thesis Overview
<p>1.1 LITERATURE REVIEW<br><br> Air conditioning is a process whereby heat received from a low temperature region is transferred to a higher temperature region. Then a negative net work is being done in the system. Air conditioning system has four basic components which are the compressor, condenser, metering device or thrilling valve and an evaporator. When any of these component is faulty or damaged it will cause the air condition system not to function well or not functioning at all.<br><br> In the first place the faulty air conditioner was rehabilitated as a project by a group of students in the department of mechanical engineering 2004/2005 session.<br><br> Before working in the air conditioner by the group in the year 2005 the following fault were dictated.<br><br>1. It has low pumping that is the compressor not pumping any gas (refrigerant) in the system.<br><br>2. The capacitors of the fan and compressor are bad.<br><br>3. The drier was not able to filter the gas pumped by the compressor as result of blockage by impurities.<br><br>4. The whole system was dirty, this is because the air conditioner have been dumped for a very long time.<br><br>The compressor is the heart of all air conditioning system. It pumps the refrigerant to the whole system.<br><br>The metering device or the expansion device meters a given quality of refrigerant required for each unit.<br><br> In this case most of these essential components of the air conditioner which seems to be very delicate, need not be handled carelessly, when it developed any fault and again, it should not be handled by non-exports in the field of air conditioning and refrigeration.<br><br> The last group that handled the project are classified as non-exports in the field of air conditioning. We say this because an air conditioning system that has the problems outlined above needs not be repaired as they had done without replacing some of the components with a brand new spare parts and the normal size that is the size of the machine air conditioner<br><br> For instance a compressor that has low pumping action, we verified that the compressor which supposed to b e two horse power (2hp) compressor. This under sized compressor has low pumping action, 6to the air conditioning set. Because the capillaries for the two horse power compressor for the bigger than that of 1.5 horse power air conditioning set.<br><br> Again the volume of air conditioning gas being pumped was too negligible to bring about the desired cooling.<br><br> The capacitors which was bad that is not good at all.<br><br> The drier which was blocked up by impurities was changed and replaced with a new one. As a result, its caused by poor cycling of refrigerant through. The copper capillary of the air conditioner which we repaired by replacing the drier with a new one. Through we can still be in a good condition.<br><br> A repaired and rehabilitated equipment is supposed to be sound both internally and externally. The people who worked in the air conditioner before, were unable to spray the air conditioner which has many scratches as a result of their work.<br><br> Sincerely speaking and other criteria that contributed immensely to the braked own of the air conditioner was poor maintenance.<br><br> Plant maintenance is the upkeep of plant safe working state. Plant maintenance is divided in to planned preventive and breakdown maintenance were sub-divided.<br><br> Thus this report encomprises, urges the series of job done to arrive at a meaningful randy to breakdown problem.<br><br> Considering space, volume and relevance we will limit our write up (thesis) to the direct and practiced work of all the air conditioner.<br><br> In the first place we used the basic procedure in tracing a fault like diecking of leakage with soap solution was done, flushing of the condenser which revealed the fault of the drier (filter) was done using vacuum pump. The compressor was tasted, there was no fault only that the size was 1.5 horse power (hp) and they have opened the compressor before and welded it which is not advisable to do.<br><br> The general dean up of all dust compacted parts was done particularly without any problems following by the changing of the plug which supply electricity to the system.<br><br> The sequence of operation and fools used during the repair is recorded in ascending order over leaf.<br><br>Purchase Detail<br>Hello, we’re glad you stopped by, you can download the complete project materials to this project with Abstract, Chapters 1 – 5, References and Appendix (Questionaire, Charts, etc) for N5000 ($15) only,<br>Please call 08111770269 or +2348059541956 to place an order or use the whatsapp button below to chat us up.<br>Bank details are stated below.<br><br>Bank: UBA<br>Account No: 1021412898<br>Account Name: Starnet Innovations Limited<br></p>