Rectification and repair of a faulty air conditioner | Blazingprojects Postgraduate Thesis
Home / Mechanical engineering / Rectification and repair of a faulty air conditioner

Rectification and repair of a faulty air conditioner

 

Table Of Contents


Chapter ONE

INTRODUCTION

  • 1.1Introduction
  • 1.2Background of Study
  • 1.3Problem Statement
  • 1.4Objective of Study
  • 1.5Limitation of Study
  • 1.6Scope of Study
  • 1.7Significance of Study
  • 1.8Structure of the Research
  • 1.9Definition of Terms

Chapter TWO

LITERATURE REVIEW

  • 2.1Overview of Literature Review
  • 2.2Theoretical Framework
  • 2.3Conceptual Framework
  • 2.4Previous Studies on the Topic
  • 2.5Current Trends and Developments
  • 2.6Critical Analysis of Literature
  • 2.7Identified Gaps in Literature
  • 2.8Theoretical Contributions
  • 2.9Practical Implications
  • 2.10Summary of Literature Review

Chapter THREE

SYSTEM DESIGN AND IMPLEMENTATION

  • 3.1Research Design
  • 3.2Research Approach
  • 3.3Data Collection Methods
  • 3.4Sampling Techniques
  • 3.5Data Analysis Procedures
  • 3.6Ethical Considerations
  • 3.7Research Limitations
  • 3.8Quality Assurance Measures

Chapter FOUR

SYSTEM TESTING AND EVALUATION

  • 4.1Presentation of Findings
  • 4.2Descriptive Statistics
  • 4.3Inferential Statistics
  • 4.4Comparison of Results
  • 4.5Discussion of Findings
  • 4.6Interpretation of Results
  • 4.7Implications of Findings
  • 4.8Recommendations for Practice

Chapter FIVE

SUMMARY, CONCLUSION AND RECOMMENDATIONS

  • 5.1Summary of Findings
  • 5.2Conclusion
  • 5.3Contributions to Knowledge
  • 5.4Practical Recommendations
  • 5.5Areas for Future Research

Thesis Abstract

In the mechanical Engineering department of institute of management and technology there and many machines but not all in are good shape or form.

This may be due to inadequate maintenance, which is evident in the breakdown of air conditioner. In the case of machine maintenance, the quality and effusiveness of material were well noted. Also not left behind was the cost of maintenance which was minimized and yet getting to a highly successful repairs too.

          In so long, during the repairs and rehabilitation of a faulty


Thesis Overview

<p> </p><p><strong>1.0 &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;INTRODUCTION</strong></p><p><strong>1.1 &nbsp; &nbsp; LITERATURE REVIEW</strong></p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Air conditioning is a process whereby heat received from a low temperature region is transferred to a higher temperature region. &nbsp;Then a negative net work is being done in the system. &nbsp;Air conditioning system has four basic components which are the compressor, condenser, metering device or thrilling valve and an evaporator. &nbsp;When any of these component is faulty or damaged it will cause the air condition system not to function well or not functioning at all.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; In the first place the faulty air conditioner was rehabilitated as a project by a group of students in the department of mechanical engineering 2004/2005 session.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Before working in the air conditioner by the group in the year 2005 the following fault were dictated.</p><p>1. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; It has low pumping that is the compressor not pumping any gas (refrigerant) in the system.</p><p>2. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The capacitors of the fan and compressor are bad.</p><p>3. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The drier was not able to filter the gas pumped by the compressor as result of blockage by impurities.</p><p>4. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The whole system was dirty, this is because the air conditioner have been dumped for a very long time.</p><p>The compressor is the heart of all air conditioning system. &nbsp;It pumps the refrigerant to the whole system.</p><p>The metering device or the expansion device meters a given quality of refrigerant required for each unit.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; In this case most of these essential components of the air conditioner which seems to be very delicate, need not be handled carelessly, when it developed any fault and again, it should not be handled by non-exports in the field of air conditioning and refrigeration.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The last group that handled the project are classified as non-exports in the field of air conditioning. &nbsp;We say this because an air conditioning system that has the problems outlined above needs not be repaired as they had done without replacing some of the components with a brand new spare parts and the normal size that is the size of the machine air conditioner</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; For instance a compressor that has low pumping action, we verified that the compressor which supposed to b e two horse power (2hp) compressor. &nbsp;This under sized compressor has low pumping action, 6to the air conditioning set. Because the capillaries for the two horse power compressor for the bigger than that of 1.5 horse power air conditioning set.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Again the volume of air conditioning gas being pumped was too negligible to bring about the desired cooling.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The capacitors which was bad that is not good at all.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The drier which was blocked up by impurities was changed and replaced with a new one. &nbsp;As a result, its caused by poor cycling of refrigerant through. &nbsp;The copper capillary of the air conditioner which we repaired by replacing the drier with a new one. Through we can still be in a good condition.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; A repaired and rehabilitated equipment is supposed to be sound both internally and externally. &nbsp;The people who worked in the air conditioner before, were unable to spray the air conditioner which has many scratches as a result of their work.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Sincerely speaking and other criteria that contributed immensely to the braked own of the air conditioner was poor maintenance.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Plant maintenance is the upkeep of plant safe working state. &nbsp;Plant maintenance is divided in to planned preventive and breakdown maintenance were sub-divided.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Thus this report encomprises, urges the series of job done to arrive at a meaningful randy to breakdown problem.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Considering space, volume and relevance we will limit our write up (thesis) to the direct and practiced work of all the air conditioner.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; In the first place we used the basic procedure in tracing a fault like diecking of leakage with soap solution was done, flushing of the condenser which revealed the fault of the drier (filter) was done using vacuum pump. &nbsp;The compressor was tasted, there was no fault only that the size was 1.5 horse power (hp) and they have opened the compressor before and welded it which is not advisable to do.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The general dean up of all dust compacted parts was done particularly without any problems following by the changing of the plug which supply electricity to the system.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; The sequence of operation and fools used during the repair is recorded in ascending order over leaf.</p> <br><p></p>

Blazingprojects Mobile App

📚 Over 50,000 Research Thesis
📱 100% Offline: No internet needed
📝 Over 98 Departments
🔍 Thesis-to-Journal Publication
🎓 Undergraduate/Postgraduate Thesis
📥 Instant Whatsapp/Email Delivery

Blazingprojects App

Related Research

Computer Engineering. 2 min read

Evaluating the Effectiveness of Edge Computing in Smart City Data Processing...

This research explores how effective edge computing is in processing data within smart cities. Smart cities rely on large amounts of data generated by sensors, ...

BP
Blazingprojects
Read more →
Computer Education. 3 min read

Impact of Gamified Learning on Computer Programming Skills Development Among High Sc...

This research is focused on understanding how using game-like elements—known as gamified learning—affects high school students' ability to learn and improve...

BP
Blazingprojects
Read more →
Co-operative economi. 3 min read

Impact of Leadership Styles on Member Engagement in Agricultural Cooperatives...

This research examines how different leadership styles influence how actively members participate and stay committed in agricultural cooperatives. Agricultural ...

BP
Blazingprojects
Read more →
Civil engineering. 4 min read

Assessing the Impact of Green Infrastructure on Urban Flood Management...

This research focuses on understanding how green infrastructure can help manage and reduce flooding in urban areas. Green infrastructure includes features like ...

BP
Blazingprojects
Read more →
Chemistry. 2 min read

Assessment of Heavy Metal Contamination in Urban Soil Ecosystems...

This research is about examining how heavy metals such as lead, cadmium, mercury, and arsenic have accumulated in urban soils and assessing the level of contami...

BP
Blazingprojects
Read more →
Chemistry education. 3 min read

Impact of Inquiry-Based Learning on Undergraduate Chemistry Conceptual Understanding...

This research explores how Inquiry-Based Learning (IBL) affects how well undergraduate students understand key chemistry concepts. Inquiry-Based Learning is an ...

BP
Blazingprojects
Read more →
Chemical engineering. 3 min read

Evaluating the Efficiency of Solar-Powered Catalytic Reactors for Biodiesel Producti...

This research focuses on evaluating how effectively solar-powered catalytic reactors can be used to produce biodiesel, a renewable fuel made from vegetable oils...

BP
Blazingprojects
Read more →
Business education. 2 min read

Impact of Digital Learning Tools on Business Students' Engagement and Performance...

This research explores how using digital learning tools influences the engagement and academic performance of business students. Digital learning tools include ...

BP
Blazingprojects
Read more →
Business Administrat. 3 min read

Impact of Transformational Leadership on Employee Innovation in Tech Firms...

This research looks at how a leadership style called transformational leadership influences innovation among employees in technology companies. Transformational...

BP
Blazingprojects
Read more →
WhatsApp Click here to chat with us